HTTP API Command List


HTTP API Overview

The HTTP API is not available in [AP Mode] - WiFi is required!

The API allows for “headless” control of the Parking Assistant system via simple HTTP requests. It’s essentially a remote control that lives in your browser’s address bar or your favorite automation script. Unlike MQTT, the API does not require third-party intermediaries (like a broker) or complex configuration. Commands are issued as standard URLs:

http://[your-controller-ip]/api?...

⚠️ Assign a Static or Reserved IP Address to the Controller
As covered in the Onboarding topic, it is recommended that you assign a static or reserved IP address to the controller. Otherwise, if you create HTTP API calls in a third-party system (such as Home Assistant) and the controller’s IP address changes, these automations will break and require an updating of the automation to use the new IP.

Even though the method to send commands is different, the HTTP API has many of the same caveats and restrictions as using a similar MQTT command. Some of those limitations are listed here, but a review of the MQTT commands may be helpful even if you aren’t planning on using MQTT.

Command Types

The HTTP API consists of two different types of commands:

  • SET Commands: These ‘set’ a value or parameter on the system. Unless otherwise noted, if a command is valid and accepted, a status code of 200 and simple “OK” text string will be returned to the browser or calling application. If invalid, then a status code of 404 and an error message will be returned..

    • Some calls may offer more than one option (e.g. ?ledbrightness= and ?brightness=) that perform the same operation. Others accept alternate values (e.g. ON, 1, TRUE) that are equivalent.
  • GET Commands: These do not modify the system, but simply return data from the system back to the calling routine or browser. All GET commands must be issued separately.

Command Chaining (SET Commands)

Some SET commands can be combined into a single HTTP call by concatenating them with an ampersand (&).

Example: http://[controller-ip-address]/api?ledbrightness=120&ledcolor=ff0000

🔍 Combined Command Format
When combining commands, the first command following the /api is prepended with the question mark (?) and any additional commands are prepended with the ampersand (&) as shown in the above example.

Other commands must be sent as the only command in the URL.


SET Commands

These commands, unless otherwise noted, are used to modify the ACTIVE state of the system. Commands marked NO in the “Multi” column must be sent as standalone requests and cannot be combined with other commands.

🔍 Passing Colors
Color code parameters can be passed as either an RGB string (e.g. ?color=255,255,0) or a HEX color string (?color=ffff00), but you must omit including a # with HEX strings as this symbol has special meaining in a URL string.

Command Parameter(s) Returns Multi Example / Notes
sensoroverride
overridesensor
ON/1/TRUE or
OFF/0/FALSE
200 / OK Yes Enables or disables the sensor override.
ledstate
state
ON/1/TRUE or
OFF/0/FALSE
200 / OK Yes Turns the LED strip on or off.
ledcolor
color
manualcolor
RGB or HEX
color string
200 / OK Yes Sets the active LED color.
ledbrightness
brightness
0 - 255 200 / OK Yes Sets the active LED brightness. If 0 is passed, the LED state will also be set to off. Values greater than 0 will toggle the LEDs on if they were off.
sleepbrightness
brightnesssleep
0 - 255 200 / OK Yes Sets the brightness of the indicator LEDs when the system is in standby mode. Will not impact current state of the LEDs.
colorwake RGB or HEX
color string
200 / OK Yes Sets the LED color for the Wake Zone. Can pass an RGB or HEX string (without leading #).
coloractive RGB or HEX
color string
200 / OK Yes Sets the LED color for the Active (approach) Zone. Can pass an RGB or HEX string (without leading #).
colorparked RGB or HEX
color string
200 / OK Yes Sets the LED color for the Parked Zone.
colorbackup RGB or HEX
color string
200 / OK Yes Sets the LED color for the Backup Zone. Also used for the lateral guidance color if a side sensor is installed and enabled.
colorstandby RGB or HEX
color string
200 / OK Yes Sets the LED color for indicator LEDs when the system is in standby mode.
ledeffect
effect1
Out-In, In-Out, Full-Strip, Full-Strip-Inv, Solid 200 / OK Yes Sets LED effect for the Active (approach) zone. Must match one of the predefined effects.
distwake 12-192 (inches)
305-4980 (mm)
200 / OK Yes Sets the Wake zone distance. Parameter range depends upon the system’s unit settings (inches or millimeters). Out-of-range values will be constrained to the appropriate minimum or maximum value.
distactive
diststart
12-192 (inches)
305-4980 (mm)
200 / OK Yes Sets the Active (approach) zone distance.
distpark 12-192 (inches)
305-4980 (mm)
200 / OK Yes Sets the Parked zone distance.
distbackup 12-192 (inches)
305-4980 (mm)
200 / OK Yes Sets the Backup zone distance.
sidedistleft 2 - 48 (inches)
50 - 1220 (mm)
200 / OK Yes Sets the Side sensor LEFT distance. Ignored if side sensor is not installed or disabled.
sidedistright 2 - 48 (inches)
50 - 1220 (mm)
200 / OK Yes Sets the Side sensor RIGHT distance. Ignored if side sensor is not installed or disabled.

Additional Command Notes

⚠️THE API ONLY UPDATES “ACTIVE” SETTINGS
When system settings (such as LED brightness or zone color/distances) are updated via the API, it only changes the current ‘Active’ setting. If the system reboots for any reason, changes will be lost and the last saved ‘defaults’ will be loaded.

To update save any changes made as the new ‘Defaults’, a direct command can be issued (see below) to force a save of the current active values.

Constraining Numeric Values
For commands where the parameter is a numeric value range, out-of-range values are ‘constrained’ to a valid value. For example, given a payload range of 50-100, passed values < 50 will be set to 50. Passed values > 100 will be set to 100.

However, the API processing does not validate distances as it does on the web page. Using the API, you can set a parked zone that is further away than the active zone. In this case, the system would not respond appropriately. Use caution when manually setting distances via the API and assure the final zone settings are appropriate.


GET Commands

These commands retrieve data and do not modify settings. They must be sent individually and cannot be combined in a single URL statement. A parameter is required, but ignored for processing. Using a parameter of 1 is recommended.

Command Parameter(s) Returns Example / Notes
ping 1 OK
or
-48 / Timeout
/api?ping=1
Returns OK if successful.
Returns ERR_CONNECTION_TIMED_OUT if not found.
ipaddress 1 IP Address /api?ipaddr=1
Returns IP address of controller.
macaddress 1 MAC Address Returns the MAC address of the ESP32

DIRECT Commands

The commands loosely correspond to the Controller Commands found on the main web page, but provide a way to initiate some system functions via MQTT.

1️⃣ Payloads Ignored
For these commands, a payload is required but ignored when processed. It is recommended that you simply pass a “1” as the payload for each of these special direct commands.

Note the omission of /api in the URL. If a browser is used to send the command, then the corresponding web app page is returned/opened.

Controller-Specific Direct Calls

Note: Those commands shown with Browser Only in the notes are only applicable when called from a browser as they open an interactive web page from the application.

Command
http://[ip_address]...
Parameter(s) Returns Notes
/restart none Web Page Reboots the targeted controller.
/otaupdate none Web Page Places targeted unit in OTA Update mode.
/firmwareupdate none Web Page Browser only. Launches the firmware update page.
/configdump none Web Page Browser only. Opens up the configuration dump page from the web application and lists all settings currently saved in the config.json file.
/info none Web Page Browser only. Opens up the system information page from the web application with system and config details.
/infojson none JSON Payload Returns a JSON payload with the system information. This could be parsed and used by a third-party system.
<- Previous: MQTT Topics & Payloads Next: Home Assistant Discovery ->